高壓ZW32真空斷路器產(chǎn)品概述:
ZW32-12戶外高壓柱上真空斷路器適用于三相交流50Hz,額定電壓12KV及以下的電力配電系統(tǒng),主要用于開(kāi)斷關(guān)合線路的負(fù)荷電流、過(guò)載電流及短路電流,也可作為農(nóng)網(wǎng)和小型電力系統(tǒng)的分段開(kāi)關(guān),是城網(wǎng)農(nóng)網(wǎng)無(wú)油化改造的升級(jí)換代產(chǎn)品。具有體積小,重量輕,防凝露、免維護(hù)等特點(diǎn),能適應(yīng)較低惡劣的氣候條件和污穢環(huán)境。
高壓ZW32真空斷路器環(huán)境使用條件:
1、海拔高度不超過(guò)2000米;
2、周圍空氣溫度:-45℃~+65℃;日溫差:日變化25℃;
3、風(fēng)速不大于35m/s;
4、無(wú)易燃、baozha危險(xiǎn)、化學(xué)腐蝕及劇烈震動(dòng)的場(chǎng)所。
高壓ZW32真空斷路器結(jié)構(gòu)特點(diǎn):
該斷路器由三相支住、機(jī)構(gòu)箱組成,結(jié)構(gòu)簡(jiǎn)單明了,三相支柱及電流互感器采用戶外環(huán)氧樹(shù)固體或硅橡膠絕緣,具有耐高低溫、耐紫外線、耐老化等優(yōu)點(diǎn);采用小型化彈簧操動(dòng)機(jī)構(gòu),分合閘能耗低、機(jī)構(gòu)傳動(dòng)輸出采用主軸滑動(dòng)方式,無(wú)扭力損耗,分合傳動(dòng)件少,可靠性高;電流互感器安裝于動(dòng)端出線,二次采用插拔結(jié)構(gòu),維護(hù)更換方便。
ZW32-12高壓真空斷路器安裝,使用與維護(hù):
3.1 開(kāi)箱后應(yīng)檢查柱上斷路器絕緣罩有無(wú)損壞,產(chǎn)品銘牌、合格證是否與實(shí)物相符。
3.2 柱上斷路器投入運(yùn)行前,應(yīng)仔細(xì)核對(duì)各操作元件的額定電壓、額定電流與實(shí)際情況是否相符。并用機(jī)構(gòu)所具有的合分閘方式進(jìn)行試操作,以檢查各項(xiàng)指標(biāo)是否正確。
3.3 斷路器可以分單桿架設(shè),也可雙桿架設(shè)(如圖二、三、四、五所示)。
3.4 本柱上斷路器因其特殊的設(shè)計(jì)結(jié)構(gòu)確保用戶在使用中長(zhǎng)期免維護(hù)。
3.5 用戶不得隨意更換使用與原型號(hào)規(guī)格不一致的電器元件。
3.6 操作人員應(yīng)初步了解機(jī)構(gòu)的性能及安裝調(diào)整、維護(hù)知識(shí),對(duì)運(yùn)行中問(wèn)題應(yīng)予以記錄,必要時(shí)可